Comtrol AT Commands for SmartACFL Manuale Utente Pagina 137

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 172
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 136
Command Reference Manual
100722A
Conexant
5-15
5.4.11 +FCIG: - Report the Polled Station ID
Syntax: +FCIG: “< ID string>” Polled Station ID
This response reports the received transmit station ID string, if any. This message is generated in execution of Originate,
Answer, +FDT, or +FDR commands.
5.4.12 +FDTC: - Report the Polled Station Capabilities
Syntax: +FDTC: “< string>” Polled Station Capabilities
If the answerer has a document to poll, it would be communicated to the originator in bit 9 of the DIS frame. The originating
station may elect to transmit a fax, and later, send SIG and DTC frames to pick up the polled document. The answering
station would report the incoming DTC frame via the +FDTC: response message after command mode is canceled with the
AT+FDR command.
5.4.13 +FPOLL - Indicate Polling Request
Syntax: +FPOLL:
This message is sent to the DTE if the received DIS message indicates that the remote station has a document to poll (by bit
9 in the DIS) and polling has been enabled with the AT+FSPL command. The DTE may then decide to receive rather than
transmit.
Vedere la pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 171 172

Commenti su questo manuale

Nessun commento