NIAS/MPR Installation and Configuration for NetWare 5.x 18
NIAS/MPR Installation and Configuration for NetWare 5.x
This discussion assumes the following:
You have installed the RocketPort or RocketModem board(s) in the server
The board(s) have passed the hardware diagnostic
You have installed the driver (AIORCKT.NLM)
You have determined which I/O addresses are used by the boards you have installed
You have not loaded the driver manually, using the load aiorckt command
The inetcfg module provides the proper mechanisms for loading and configuring the driver. If necessary, down
and restart the server to make sure that the driver is not loaded.
The following instructions assume a single RocketPort or RocketModem board, but the process is similar
when multiple boards are installed. Follow these steps:
1. At the server console, enter load NIASCFG.
2. Select Configure NIAS.
3. Select Protocols and Routing.The Internetworking Configuration menu displays:
4. Select Boards. The list of configured boards displays:
5. Press the Insert key to add a new board.